SIMPLWINDOWS
NAME:
Compool CP3800
CATEGORY: Miscellaneous
VERSION: 1.0
SUMMARY: This module implements Version 0.1 of the Compool
Protocol Definition. Control is accomplished by sending a
single control packet, consisting of 16 bytes, to the
Power Center of the Compool system (LX-3xxx). The
protocol consists of two types of packets: a "basic
control packet," and a "basic acknowledgement packet."
The basic control packet allows the Crestron control
system to:
1. Toggle on/off state of the Spa, Pool, Aux 1-7
2. Enable or disable the Spa side remote(s)
3. Cancel any current circuit delays (not
recommended)
4. Change/cancel heat source/method for Spa or
Pool
5. Change/set desired temperature for Spa and/or
Pool
6. Control dimmers (if unit has dimmers installed)
The basic acknowledgement packet allows the Crestron
control system to determine:
1. Current state of the Spa, Pool, Aux 1-7
2. Current state of Heater and Solar for both Spa
and Pool
3. Whether the LX-3xxx is in Service Mode (no
commands should be sent)
4. Current state of Spa side remote(s)
5. Current heat source selection
6. Solar presence
7. Freeze protection mode
8. Current water and solar temperature for Spa
and Pool
9. Desired/set temperature for Spa and Pool
10. Air temperature (for Freeze sensor; not intended
to be accurate measure of air temp)
11. Status of temperature sensors
12. Current time of day stored in LX-3xxx unit
The hardware interface is a simple half duplex RS-485
differential pair.
GENERAL NOTES:
Carefully follow the directions in the "Compool Cp3800
Installation & Operating Instructions" for wiring power
and temperature sensors. If your temperature sensors
are not wired correctly, you will see an error number
appear in the CP3800 control panel; refer to the
Compool manual for assistance in determining the
nature of the error and in resolving the difficulty.
Please note that this module was written to handle and
display all temperature values in degrees Fahrenheit.
There is a digital input to the module specifying a toggle
display between Fahrenheit and Celsius, but this input
will only effect the temperature display on the CP-3800
control panel.
Also note that not all outputs will be valid for all models
of the Power Center. Make sure to only use those
outputs that are valid for the model you are actually
controlling.
The following inputs have different functions depending
Seitenansicht 0
1 2 3 4 5

Inhaltsverzeichnis

Seite 1

SIMPLWINDOWS NAME: Compool CP3800CATEGORY: MiscellaneousVERSION: 1.0SUMMARY: This module implements Version 0.1 of the Compool Protocol Definition.

Seite 2

on the model of the Compool system:Note that Aux4, 5, 6, and 7 are not available on the 3400. Aux6 and 7 are not available on the 3600. During normal

Seite 3

parameters should be entered as decimal values, representing a temperature in degrees Fahrenheit. Please note that, for each target, the "High_

Seite 4

remote is onC/F DWhen high/active, indicates that Cp3xxx display is in degrees CSpa_Heater_On DReal feedback indicating heat source for spa is onPool

Seite 5

Error_5 DWhen "high" indicates that an error has been detected at the spa side remote (like it has been disabled)Spa_Heater_On_(Model_3830